StarliteOperating InstructionsAll-in-one
10 GOSSEN Foto- und Lichtmeßtechnik2.1.1 Automatic display illuminationWhen the lighting conditions are poor (about EV 4 or less), the background ligh
GOSSEN Foto- und Lichtmeßtechnik 113 Operating elements3.1 ISO – ISO2Selecting the film speedYou can select two different film speeds with the ISO and
12 GOSSEN Foto- und Lichtmeßtechnik3.2 Function With the function buttons you can select the meas-uring modes ambient light or flash light .Keep th
GOSSEN Foto- und Lichtmeßtechnik 133.5 Measuring head with optical viewfinder1° or 5° Flat diffuser– spherical diffuserThe measuring head is the optic
14 GOSSEN Foto- und Lichtmeßtechnik4 This is how the Starlite works4.1 Incident and reflected light measuringYour Starlite is designed for the enthusi
GOSSEN Foto- und Lichtmeßtechnik 154.1.3 Reflected light – 1° Spot measuringFor this function, the setting ring at the base of the diffuser must be
16 GOSSEN Foto- und Lichtmeßtechnik5 Measuring functions – Ambient light – Select with the left function button ambient light (the last stored mea
GOSSEN Foto- und Lichtmeßtechnik 175.2 Exposure time priority – Press the measuring button to take a measurement.– The measured f/stop appears on th
18 GOSSEN Foto- und Lichtmeßtechnik5.4 Contrast measuringin the t and EV functionsContrast of the subjectReflected light measuringthrough the viewfind
GOSSEN Foto- und Lichtmeßtechnik 195.5 Averaging value AVR in the t and EV functionsReflected light measuring through the viewfinder– The first measur
2 GOSSEN Foto- und Lichtmeßtechnik1 Preparation ... 71.1 Battery ...
20 GOSSEN Foto- und Lichtmeßtechnik5.6 Selecting the exposure time valuesIn addition to the standard full time values, also half time values (1/2 TV)
GOSSEN Foto- und Lichtmeßtechnik 215.7 Taking measurements in the zone systemThis function is mainly used to cope with subject contrasts in the field
22 GOSSEN Foto- und LichtmeßtechnikAfter each measurement using the measuring but-ton the following data are stored and displayed:– the symbol ZONE
GOSSEN Foto- und Lichtmeßtechnik 236 Measuring functions– Flash light In essence, flash measuring can be carried out in all diffuser settings (inciden
24 GOSSEN Foto- und Lichtmeßtechnik6.2 Flash calculation for changed measuring timesIf the measurement shows that the ambient light part in relation t
GOSSEN Foto- und Lichtmeßtechnik 256.4 Average value– Take first measurement using measuringbutton – Measure up to a further 8 flashes using the avera
26 GOSSEN Foto- und Lichtmeßtechnik7 Taking a measuring outside the measuring range – display range7.1 Taking a measurement outside the measuring rang
GOSSEN Foto- und Lichtmeßtechnik 278 Setting and measuring correction values and extension factors8.1 Setting correction values– By simultaneously pre
28 GOSSEN Foto- und Lichtmeßtechnik8.1.1 Measuring correction values Correction values can also be measured directly. An evenly illuminated surface an
GOSSEN Foto- und Lichtmeßtechnik 299 CINE meter for cinematographers – PHOTOMETRYBy actuating the DIP 1 switch, the Starlite can be converted easily a
GOSSEN Foto- und Lichtmeßtechnik 3Retractable diffuserMeasuring head with optical viewfinderISO buttonISO 2 buttonSocket for the flash sync cordDiffus
30 GOSSEN Foto- und Lichtmeßtechnik9.3 Setting the shutter angleThe shutter angle in the Starlite is preset at the factory to 180°.If you are working
GOSSEN Foto- und Lichtmeßtechnik 3110 Photometry10.1 Selecting the photometric display unitUse the DIP 1 switch to change over to the functions CINE/P
32 GOSSEN Foto- und Lichtmeßtechnik10.3 Measuring the luminance candela / m2 (cd/m2) or footLambert (fL)– Set the measuring head to reflected light me
GOSSEN Foto- und Lichtmeßtechnik 3311 Practical tipsPre-programming influence valuesThe Starlite determines precise exposure data in accordance with D
34 GOSSEN Foto- und Lichtmeßtechnik12 Contrast and optimal exposureThe basic rules for optimal exposure are that the brightest areas on the color reve
GOSSEN Foto- und Lichtmeßtechnik 35Negative filmIf the difference between important bright and dark areas does not exceed two stops (EV) between impor
36 GOSSEN Foto- und LichtmeßtechnikSome types of color film come with special infor-mation or notes with instructions for shots with long exposure tim
GOSSEN Foto- und Lichtmeßtechnik 3713 Technical dataMeasuring capabilitiesIncident light measuring(option of flat or spherical diffusor)Reflected ligh
38 GOSSEN Foto- und LichtmeßtechnikFlash calculation for altered measuring times1 s to 1/1000 s Multiple flash calculationup to 9 flashesCINE speedsSt
GOSSEN Foto- und Lichtmeßtechnik 3914 Serial interfaceOn the outside of the Starlite there is an integrated serial interface. 15 ServiceIf repair or a
4 GOSSEN Foto- und LichtmeßtechnikOptical viewfinderMeasuring buttonMeasuring buttonEyelet Serial interfaceSetting wheelfor connection cordLens cover
Printed in Germany • Subject to change without notice • 15080 • 2/6.01 Bogen Photo Corp.565 East Crescent Avenue, Ramsey, NJ 07446-0506Tel: (201) 8
GOSSEN Foto- und Lichtmeßtechnik 5Serial numberBattery DIP switchesBatterycompartment cover
6 GOSSEN Foto- und LichtmeßtechnikYour Starlite is the top device in the GOSSEN-product range and represents a real all-in-one light meter. It combine
GOSSEN Foto- und Lichtmeßtechnik 71 Preparation1.1 BatteryThe Starlite works with a 1.5 V AA battery (Alkaline-manganese or corresponding rechargeable
8 GOSSEN Foto- und Lichtmeßtechnik1.3 Selecting the function groups:DIP switches in the battery compartmentIn addition to the standard functions, your
GOSSEN Foto- und Lichtmeßtechnik 92 Display panel2.1 The display panel and its elements1 Function– Ambient light – Flash light 2 Measuring head– Inc