32 GOSSEN Foto- und Lichtmeßtechnik
10.3 Measuring the luminance candela / m
2
(cd/m
2
) or footLambert (fL)
Set the measuring head to reflected light
measuring –1° or 5° . The luminance
function is set and shown in the display.
Focus on the subject to be measured via the
viewfinder
Take a measurement using the measuring
button
The selected display unit and measured
luminance are displayed.
10.4 Measuring time-integral values
(lxs, fcs, cds/m
2
, fLs)
Set measuring head to reflected light
or incident light measuring.
The corresponding display unit is set
and shown in the display.
Set with the right function button the
function flash light .
Pre-select the desired measuring time using
the setting wheel; this can be found on the right
hand side of the display panel. Activated half
time stop increments are also displayed.
Start flash measuring using the measuring but-
ton – cord/noncord (chapter 6.1, page 23).
The measured value, which is calculated to
1 second, is shown in the pre-selected display
unit.
By preselecting the measuring time, the ambient
light part is correspondingly taken into account.